Power-up Failure: First, check if the safety protective cover is properly closed, then inspect the power supply and air source to ensure they are correctly installed and secure. Make necessary adjustments or tightening.
Feeding Roller Malfunction: Check if there is an alarm code from the servo driver, and contact after-sales service if needed. Also, check if the magnetic induction switch on the cylinder is lit, and adjust its position if it's not.
Automatic Operation Failure to Rebound: Inspect if the lower induction magnetic switch of the cutting knife cylinder is lit, and adjust the switch position until it lights up.
Cutting Blade Failure to Cut: Open the safety cover of the equipment and check if the knife slot under the circular knife has risen; if not, use the "Knife Slot" button on the touch screen for adjustment.
Automatic Machine Shutdown: Check the setting value of the "Delay Shutdown" parameter on the touch screen, the standard setting is 900. Also, ensure the safety cover is correctly closed.
Cleaning: Regularly clean the machine to remove dust and debris, preventing blockages that could cause malfunctions.
Lubrication: Lubricate the moving parts of the machine regularly according to the manufacturer's guidance.
Blade Inspection: Regularly check the sharpness and secureness of the blades, replacing or tightening as necessary.
Electrical Check: Have a professional regularly inspect the electrical system to ensure there are no risks of short circuits or electrical leakage.
Training: Ensure all operators are professionally trained and familiar with the machine's operating procedures.
Protection: Wear appropriate protective gear when operating, such as work hats, safety goggles, and gloves.
Emergency Situations: Understand the emergency stop procedures and take immediate action if you feel anything is unsafe.